04

Load cell SQB-A 3-10t



Load cell beam upon bend or shear is applied in systems of dosing, floor scales of average lifting capacity, tanks, and floor systems of weighing including electronic balance for weighing of animals.

Electronic scales are more often completed by resistive-strain sensors of weight (load cell). Subject to type of scales and conditions of operation for measuring of effort transmitted by receptacle platform to weight sensor the corresponding type of load cell is selected. There are some main types of load cells subject to type of resilient member and applicable effort of deformation. Consider load cell – beam upon shear.

Load cell – beam upon shear is the most widespread type of load cell and widely applied in construction of platform and hopper scales. Sensor is fixed on receptacle by bolted connection and is borne on floor by supporting foot regulated on height. Changing height of supporting foot it is possible to grade difference upon base level on which scales are installed.

Engineering data

4 wires:

  1. Exciter (+) Red
  2. Exciter (-) Black
  3. Impulse (+) Green
  4. Impulse (-) White
Rated load 3, 5, 7.5, 10t Insulation resistance ≥5000 mΩ
Accuracy class 0.03 Operating temperature rated range -10~+ 40ºС
Sensitivity 3.0± 0.003mV/V Temperature service range -30~+ 70ºС
Non-linearity ±0.03% F.S Safety load limit 150% F.S
Hysteresis error ±0.03% F.S Breaking load 200% F.S
Creep (30min) ±0.02% F.S Excitation rated range 10~12 V DC
TC ZERO ±0.02% F.S/10ºС Protection class IP68
TC INTERVAL ±0.02% F.S/10ºС Material Alloyed steel
Input resistance 400±20Ω Cable Length: 4.2m(3t-5t)
Output resistance 352±3Ω 5m (7.5t-10t)