Load cell QS-А
Basic device of the up-to-date weight measuring systems is load cells, construction of which is based on resilient mechanical member which is subject to deformation with overlaid on it strain-gauge bridge consisting of resistive-strain sensors connected in different electric networks. With effect of external load to sensor as a result of deformation symmetry of measuring bridge is upset and electrical signal proportional to applied effect to sensor is appeared at measuring terminals.
Engineering data
4 wires:
- Exciter (+) Red
- Exciter (-) Black
- Impulse (+) Green
- Impulse (-) White
Rated load | 5t, 10t, 15t, 20t, 25t, 30t, 40t, 50t | Operating temperature rated range | -10~+ 40ºС |
---|---|---|---|
Accuracy class | С2~С3 | Temperature service range | -30~+ 70ºС |
Sensitivity | 2.0±0.002mV/V | Safety load limit | 150% F.S |
Non-linearity | ±0.03% F.S | Breaking load | 250% F.S |
Hysteresis error | ±0.03% F.S | Excitation rated range | 10~12 V DC |
Creep (30min) | ±0.02% F.S | Protection class | IP67 |
TC ZERO | ±0.02% F.S/10ºС | Material | Alloyed steel |
TC INTERVAL | ±0.02% F.S/10ºС | Stainless steel | |
Input resistance | 750±10Ω | Cable | |
Output resistance | 702±3Ω | Length |
|
Insulation resistance | ≥5000 mΩ |
|